Shrnutí obsahu

Strany 1 - Hoshizaki

Hoshizaki “A Superior Degree of Reliability” www.hoshizaki.com ModelIM-500SAAStackable Square Cuber Hoshizaki America, Inc. SERVICE MANUALNumber: M02

Strany 2

10ET temperature is recorded 30 seconds after PM energizes. Water temperature correction value (CB Setting 13) is added to ET temperature and this is

Strany 3 - IMPORTANT

11C. Service Diagnosis TableFirst see "III.G. Error Codes." If there are no recorded errors, refer to the table below.No Ice Production - Po

Strany 4 - Important Safety Information

12Low Ice Production - Possible CauseLong Harvest Cycle1. Evaporator a) Scaled up.2. Refrigerant Charge a) Low.3. Control Board a) Thermistor connecti

Strany 5 - WARNING, continued

13Large-Hole Cubes - Possible Cause (Also see III.H.1. Dimple Diameter") 4. Icemaker Location a) Insufficient clearance.b) Ambient temperature to

Strany 6 - A. Construction

14D. Bin Control Check and Cleaning1. Bin Control CheckThis appliance uses a lever-actuated proximity switch to control the ice level in the storage b

Strany 7 - 1. Air-Cooled Model (SAA)

152. Bin Control CleaningScale may build up on BC. Scale can cause the actuator paddle and magnet to stick. In this case, BC should be cleaned. WARNIN

Strany 8

16E. Evaporator Thermistor CheckTo check thermistor resistance, follow the steps below.1) Turn off the power supply. 2) Remove the front panel. Move t

Strany 9 - B. Sequence of Operation

17III. Controls and AdjustmentsA. Control SwitchThe control switch has three positions: OFF for power off, ICE for icemaking, and WASH to energize the

Strany 10

181. Control Board Layout• CN16 ConnectorActuator Motor Position Sensor (Hall IC) Input• CN11 ConnectorBin Control Input• CN13 ConnectorEvaporator (Cu

Strany 11 - C. Service Diagnosis Table

19C. Control ButtonsThe control board features RESET, SERVICE 1, and SERVICE 2 Buttons1. RESET Button• Press briey to go to initial harvest cycle.• P

Strany 12

2 WARNINGOnly qualied service technicians should install and service the appliance. To obtain the name and phone number of your local Hoshizaki Certi

Strany 13

20D. Control Board SettingsNOTICEFailure to maintain factory settings may adversely affect performance and warranty coverage. For more information, co

Strany 14

21Control Board (CB) Setting MenuCategory No. Item RangeIM-500SAA DefaultWater Supply, continued12Freeze Cycle Water Supply Time 1: Partial Drain (CB

Strany 15 - WARNING

22Control Board (CB) Setting MenuCategory No. Item RangeIM-500SAA DefaultCompressor 37Compressor Output SelectionDO NOT ADJUST0: X8 (DC Relay) On1: X1

Strany 16

23Control Board (CB) Setting MenuCategory No. Item RangeIM-500SAA DefaultWater Tank Ice Control & Harvest Cycle Low Temperature Control74Water Tan

Strany 17 - B. Control Board

24Control Board Information DisplayNo. Item DescriptionHistory Cleared by Pressing and Holding SERVICE 1 and SERVICE 2 Buttons Simultaneously for 5Se

Strany 18 - "IM" Control Board

25F. Control Board Model Code Setting1. Control Board Replacement WARNING• This appliance should be diagnosed and repaired only by qualied service pe

Strany 19 - C. Control Buttons

265) Press the "SERVICE 1" button to increase the rst digit in the display and the "SERVICE2" button to increase the second digi

Strany 20 - D. Control Board Settings

27G. Error CodesWhen the control board detects an error, the display shows one of the following error codes in the display mode. Error codes other tha

Strany 21

28Error CodesError CodeProblem Corrective Action/Reset DetailsEE (E5)High Evaporator TemperatureIf evaporator temperature 140°F (60°C) or higher for 5

Strany 22

293) Press the "SERVICE 2" button to lower freeze cycle termination temperature setting (Control Board Setting 2). Temperature setting lower

Strany 23

3CONTENTSImportant Safety Information ... 4I. Constructi

Strany 24

30IV. Refrigeration Circuit and Component Service Information WARNING• This appliance should be diagnosed and repaired only by qualied service person

Strany 25

312. Brazing WARNING• R-404A itself is not ammable at atmospheric pressure and temperatures up to 176°F (80°C).• R-404A itself is not explosive or po

Strany 26

325) Disconnect the gauge manifold hose from the vacuum pump and attach it to a refrigerant service cylinder. Remember to loosen the connection and pu

Strany 27 - G. Error Codes

33Water Pan AssemblyRefer to illustration for assembly.Icemaking Assembly and Cam MechanismRefer to illustration for assembly.1. Water Tank2. Water Pl

Strany 28 - H. Quick Adjustments

34V. MaintenanceThe maintenance schedule below is a guideline. More frequent maintenance may berequired depending on water quality, the appliance&apos

Strany 29 - Water Tank Drain Pipe

35VI. Preparing the Icemaker for Periods of Non-UseNOTICE• When storing the appliance for an extended time or in sub-freezing temperatures, follow the

Strany 30

36VII. DisposalThe appliance contains refrigerant and must be disposed of in accordance with applicable national, state, and local codes and regulatio

Strany 31

37VIII. Technical InformationWe reserve the right to make changes in specications and design without prior notice.A. Specication Data1. IM-500SAAAC

Strany 32

38B. Performance DataPressure data is recorded at 5 min. into freezing cycle. The data not in bold should be used for reference only.1. IM-500SA

Strany 33

39C. Wiring Diagram1. IM-500SAA

Strany 34 - V. Maintenance

4Important Safety InformationThroughout this manual, notices appear to bring your attention to situations which could result in death, serious injury,

Strany 35

5 WARNING, continued• The appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or

Strany 36 - VII. Disposal

6I. Construction and Water/Refrigeration Circuit DiagramA. Construction1. Air-Cooled Model (SAA)Model Shown: IM-500SAAWater TankBin ControlEvaporator

Strany 37 - A. Specication Data

7B. Water/Refrigeration Circuit Diagram1. Air-Cooled Model (SAA)Thermostatic Expansion ValveEvaporatorEvaporator ThermistorWater TankWater PumpCondens

Strany 38 - B. Performance Data

8II. Sequence of Operation and Service DiagnosisA. Sequence of Operation Flow ChartLegend: AMD–actuator motor downAMU–actuator motor upBC–bin controlC

Strany 39 - C. Wiring Diagram

9B. Sequence of Operation1. Startup CycleWhen power supply is turned on, "on" appears on CB display and HGV energizes. 30sec. later, harves

Komentáře k této Příručce