Shrnutí obsahu

Strany 1 - F-801MWH/-C

SERVICE MANUAL June 7, 2004MODELHOSHIZAKIMODULAR FLAKERF-801MAH/-CF-801MWH/-C 73113 June 15, 2005ISSUED:NO:REVISED:

Strany 2 - IMPORTANT

10F-801MWH/-CWater SupplyInletJunction BoxWaterRegulatorCompressorDrierControl Water ValveBin ControlIce ChuteEvaporatorExpansionValveFlush WaterValve

Strany 3 - CONTENTS

112. Control Box LayoutF-801MAH/-CNote: The above component names are identical with the wiring label, but not withthe parts list.PRESSURESWITCHCONNEC

Strany 4

12F-801MWH/-CPRESSURESWITCHCONNECTORSTARTCAPACITORRUNCAPACITORWATER CONTROL RELAYTRANSFORMERGEARMOTORRELAYFLUSHICEGEAR MOTORPROTECT R

Strany 5 - 1. Icemaker

13III. Technical Information1. Water Circuit and Refrigeration CircuitF-801MAH/-C

Strany 6

14F-801MWH/-C

Strany 7

152. Wiring DiagramsF-801MAH/-C, F-801MWH/-C

Strany 8

163. Sequence of Electrical Circuit[a] When power switch is moved to “ON” position and flush switch to “ICE” position, water starts to be supplied

Strany 9 - 1. Construction

17[b] When reservoir has been filled, gear motor starts immediately.

Strany 10

18[c] Compressor starts about 60 sec. after gear motor starts.

Strany 11 - 2. Control Box Layout

19[d] Bin control operates, and about 6 sec. later, compressor and gear motor stopsimultaneously.

Strany 12

2IMPORTANTOnly qualified service technicians should attempt to service or maintain thisicemaker. No service or maintenance should be undertaken until

Strany 13 - III. Technical Information

20[e] Low water (except water-cooled model).

Strany 14

21[f] Low water (water-cooled model), or dirty air filter (air-cooled model), pressure switch to “OPEN”, compressor and gear motor operate in

Strany 15 - 2. Wiring Diagrams

22[g] When flush switch is moved to “FLUSH” position, flush water valve opens and flushes reservoir and evaporator.

Strany 16

23[h] When flush timer operates (for 15 min. every 12 hours).

Strany 17

24[i] When 208-230V are supplied to circuit protect relay, it protects the circuit from miswiring. If the power supply is properly connected, the

Strany 18

25[j] When input voltage is too low, (less than 70%), gear motor fuse (1.5A) is blown causing the compressor and gear motor to turn off immed

Strany 19

26Miswiring. Circuit Protect Relay operates.)Proper wiring. The unit starts.BIN CONTROLOFF ON1. CIRCUIT PROTECTRELAY2. WATER LEVEL3.

Strany 20

271. CIRCUIT PROTECTRELAY2. WATER LEVEL3. FLOATSWITCHUPPERLOWER4. WATER CONTROLRELAY5. CONTROL WATERVALVE6. FLUSH TIMER7. FLUSH SWITCH8. FLUSH

Strany 21

281. CIRCUIT PROTECTRELAY2. WATER LEVEL3. FLOATSWITCHUPPERLOWER4. WATER CONTROLRELAY5. CONTROL WATERVALVE6. FLUSH TIMER7. FLUSH SWITCH8. FLUSH

Strany 22

295. Performance DataF-801MAHWe reserve the right to make changes in specifications and design without prior notice.APPROXIMATE Ambient Water Temp. (

Strany 23

3CONTENTSI. Specification ... 51. I

Strany 24

30F-801MWHWe reserve the right to make changes in specifications and design without prior notice.APPROXIMATE Ambient Water Temp. (F)ICE PRODUCTION Te

Strany 25

31F-801MAH-CWe reserve the right to make changes in specifications and design without prior notice.APPROXIMATE Ambient Water Temp. (F)ICE PRODUCTION

Strany 26 - 4. Timing Chart

32F-801MWH-CWe reserve the right to make changes in specifications and design without prior notice.APPROXIMATE Ambient Water Temp. (F)ICE PRODUCTION

Strany 27

33IV. Adjustment of Components1. Adjustment of Water Regulating Valve (water-cooled model only)The water regulating valve or also called “water regula

Strany 28

342. Adjustment of Flake SizeTo adjust the flake size, change the direction of the cutter head on the top of the auger,according to the following proc

Strany 29 - 5. Performance Data

35V. Service Diagnosis1. No Ice ProductionPROBLEM POSSIBLE CAUSE REMEDY[1] The icemaker willnot start.a) Power Supply 1. OFF position. 1. Move to ON p

Strany 30 - F-801MWH

36PROBLEM POSSIBLE CAUSE REMEDY[4] Water has beensupplied, Fan Motorstarts, but GearMotor andCompressor will notstart.a) Gear Motor Fuse(BUSSMAN GMD1.

Strany 31 - F-801MAH-C

372. Low Ice ProductionPROBLEM POSSIBLE CAUSE REMEDY[1] Low ice production a) Refrigerant Line 1. Gas leaks. 1. See "1. [5] a)Refrigerant Line.&q

Strany 32 - F-801MWH-C

383. OtherPROBLEM POSSIBLE CAUSE REMEDY[1] Abnormal noise a) Fan Motor 1. Bearing worn out. 1. Replace.2. Fan blade deformed. 2. Replace fan blade.3.

Strany 33 - IV. Adjustment of Components

39VI. Removal and Replacement of Components1. Service for Refrigerant Lines[a] Refrigerant RecoveryThe icemaker unit is provided with two refrigerant

Strany 34 - 2. Adjustment of Flake Size

45. Removal and Replacement of Expansion Valve ... 436. Removal and Replacement of Water Regulat

Strany 35 - 1. No Ice Production

404) Close the low-side valve and high-side valve on the service manifold.5) Disconnect the vacuum pump, and attach a refrigerant service cylinder t

Strany 36 - PROBLEM POSSIBLE CAUSE REMEDY

413. Removal and Replacement of CompressorIMPORTANTAlways install a new drier every time the sealed refrigeration system isopened. Do not replace the

Strany 37 - 2. Low Ice Production

4214) Evacuate the system, and charge it with refrigerant. For the air-cooled and water-cooledmodels, see the nameplate for the required refrigerant c

Strany 38 - 3. Other

435. Removal and Replacement of Expansion ValveIMPORTANTSometimes moisture in the refrigerant circuit exceeds the drier capacity andfreezes up at the

Strany 39

446. Removal and Replacement of Water Regulating Valve(water-cooled model only)IMPORTANTAlways install a new drier every time the sealed refrigeratio

Strany 40 - 2. Brazing

457. Removal and Replacement of Evaporator Assembly1) Turn off the power supply.2) Remove the panels.3) Move the flush switch to the "FLUSH"

Strany 41

4613) Recover the refrigerant and store it in an approved container, if required by an applicablelaw.IMPORTANTAlways install a new drier every time th

Strany 42

4726) Assemble the removed parts in the reverse order of the above procedure.WARNINGBe careful not to scratch the surface of the O-ring, or it may cau

Strany 43

48AugerMechanicalSealO-ringBearing- LowerBoltWasherCoupling- SplineRubber O-ringNylon RingBoltWasherCutterExtrudingHeadWasherSocket HeadCap ScrewEvapo

Strany 44 - (water-cooled model only)

498. Removal and Replacement of Fan Motor1) Turn off the power supply and remove the panels.2) Remove the wire connectors from the fan motor leads.3)

Strany 45

5I. Specification1. IcemakerF-801MAHWe reserve the right to make changes in specifications and design without prior notice.AC SUPPLY VOLTAGE 115/60/1

Strany 46

5010. Removal and Replacement of Flush Water Valve1) Turn off the power supply, remove the panels and close the water supply line shut-offvalve.2) Rem

Strany 47

51VII. Cleaning and MaintenanceIMPORTANTEnsure all components, fasteners and thumbscrews are securely in place afterany maintenance or cleaning is don

Strany 48

52[Water-Cooled Models]1) Turn off the power supply and wait for 3 minutes.2) Turn on the power supply and wait for 20 seconds.3) Close the water supp

Strany 49

53[b] Cleaning ProcedureThe cleaning process will remove lime deposits from the water system.1) Remove the front panel and top panel, then turn off th

Strany 50

54[c] Sanitizing SolutionDilute 2.5 fl. oz. (74 ml or 5 tbs) of IMS-II Sanitizer or a 5.25% sodium hypochlorite solution(chlorine bleach) with 5 gallo

Strany 51 - VII. Cleaning and Maintenance

5514) Replace all parts in their correct positions.IMPORTANTWhen installing the baffles, make sure that the bent surface (the one without thestuds) fa

Strany 52

5616) When the gear motor starts, remove the front panel and turn off the power supply.17) Drain out all water from the water line. See 2) and 3).18)

Strany 53

573. MaintenanceIMPORTANT1. This icemaker must be maintained individually, referring to the instructionmanual and labels provided with the icemaker.2.

Strany 54

583) Air Filter (air-cooled model only)A plastic mesh air filter removes dirt or dust from the air, and keeps the condenserfrom getting clogged. As th

Strany 55

6F-801MWHWe reserve the right to make changes in specifications and design without prior notice.AC SUPPLY VOLTAGE 115/60/1 COMPRESSOR 120 V 8.5 RLA 51

Strany 56

7F-801MAH-CWe reserve the right to make changes in specifications and design without prior notice.AC SUPPLY VOLTAGE 115/60/1 COMPRESSOR 120 V 9.4 RLA

Strany 57 - 3. Maintenance

8F-801MWH-CWe reserve the right to make changes in specifications and design without prior notice.AC SUPPLY VOLTAGE 115/60/1 COMPRESSOR 120 V 8.5 RLA

Strany 58

9II. General Information1. ConstructionF-801MAH/-CWater SupplyInletJunction BoxCondenserFan MotorCompressorDrierControl Water ValveBin ControlIce Chut

Komentáře k této Příručce

Žádné komentáře