Hoshizaki“A Superior Degreeof Reliability”www.hoshizaki.comModelsC-101BAHC-101BAH-DSC-101BAH-ADC-101BAH-ADDSSelf-Contained CubeletHoshizaki America, I
104. C-101BAH-ADDSUnits: mm [in.]
11II. Installation Instructions WARNING• The appliance must be installed in accordance with applicable national, state, and local codes and regulation
122. Built-In Installation SiteNOTICE• Do not let the weight of the counter rest on the appliance.• Do not install the appliance in a corner where the
13C. Door1. C-101BAH, C-101BAH-ADa) Door ReversalIf you would like to reverse the door swing, follow the steps below. Otherwise, skip to section "
144) Remove hinge (B) from the right side of the appliance and the 2 ller screws from the left side. Attach the 2 ller screws to the right side and
1512 34652. C-101BAH-DS, C-101BAH-ADDSa) Overlay Panel Fabrication and AttachmentIMPORTANTThe overlay panel must be crafted by a professional cabinet
16(2) Overlay Panel SpecicationUse the specication that applies to your appliance (C-101BAH-DS or C-101BAH-ADDS) and the directions that follow to p
17C-101BAH-ADDS Overlay Panel SpecicationOverlay Panel Height 27 9/16" (700 mm)Overlay Panel Width 14 13/16" (376 mm)Overlay Panel Thicknes
183) Screw the 6 threaded wood inserts into the 1/4" holes drilled in the previous step. Make sure that the inserts are threaded straight and tha
19f) Remove hinge (C1) from the top right part of the door, ip it and reattach to the bottom left. Remove hinge (C2) from the bottom right part of th
2 WARNINGOnly qualied service technicians should install and service the appliance. To obtain the name and phone number of your local Hoshizaki Certi
209) Temporarily fasten the overlay panel to the door using 2 of the M4×25 pan head screws provided. NOTICE! Ensure that the back surface of overlay p
21Snug the screws, but do not tighten.Sheet Metal BracketOverlay PanelTighten the screws.5) Fasten the overlay panel to the door using the four M4×25
227) Tighten the four M4×25 pan head screws installed in step 5. See Fig. 26.8) Replace the door gasket in its proper orientation. Reinsert the bushin
23D. Setup1) Position the appliance in the selected permanent location.2) Level the appliance from side-to-side and front-to-rear by adjusting the fee
24F. Water Supply and Drain Connections WARNINGWater supply and drain connections must be installed in accordance with applicable national, state, and
25Fig. 30Piping to approved drain. Leave a 2-inch (5-cm) vertical air gap between the end of the pipe and the drain.2-inch (5-cm) air gapFloorDrainShu
26G. Final Checklist WARNINGCHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation. Make sure that
27III. Operating InstructionsA. Important Notes About Usage WARNING• Only qualied service technicians should install and service the appliance.• Fail
28NOTICE• Protect the oor when moving the appliance to prevent damage to the oor.• If using the optional drain pump (HS-5061), test its operation ev
29B. Startup WARNINGAll parts are factory-adjusted. Improper adjustments may adversely affect safety, performance, component life, and warranty covera
3IMPORTANTThis manual should be read carefully before the appliance is installed and operated. Read the warnings and guidelines contained in this manu
30IV. MaintenanceThe appliance must be maintained in accordance with the instruction manual and labels provided with the appliance. Consult with your
31A. Maintenance ScheduleThe maintenance schedule below is a guideline. More frequent maintenance may be required depending on water quality, the appl
32B. Cleaning and Sanitizing InstructionsThe appliance must be cleaned and sanitized at least twice a year. More frequent cleaning and sanitizing may
337) Make sure at least 10 minutes have elapsed since you poured the cleaning solution over the extruding head, then move the control switch to the &q
345. Sanitizing Procedure - Final1) Using a clean funnel and hose, pour 1 qt (1 l) of sanitizing solution over the extruding head. Allow the appliance
35D. CondenserCheck the condenser once a year, and clean if required by following the steps below. More frequent cleaning may be required depending on
36E. Optional Drain Pump HS-5061If the optional drain pump (HS-5061) is installed, test its operation at least twice a year as outlined below. Note th
37V. Preparing the Appliance for Periods of Non-UseDuring extended periods of non-use, extended absences, or in sub-freezing temperatures, follow the
3814) Plug the appliance back in, then move the control switch to the "DRAIN" position. 15) Blow out the reservoir outlet hose using the com
39VI. DisposalThe appliance contains refrigerant and must be disposed of in accordance with applicable national, state, and local codes and regulation
4Important Safety InformationThroughout this manual, notices appear to bring your attention to situations which could result in death, serious injury,
40HOSHIZAKI AMERICA, INC.618 Hwy. 74 S., Peachtree City, GA 30269 USA TEL (770) 487-2331 FAX (770) 487-3360 www.hoshizaki.com 1A3094-010
5 WARNING, continued• The appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or
6I. SpecicationsA. ConstructionTop PanelIce Discharge OpeningScoop HolderFront PanelControl SwitchLouverBin Control Thermostat BulbSlopeMagnet CatchD
7C. Dimensions/Connections1. C-101BAHUnits: mm [in.]
82. C-101BAH-DSUnits: mm [in.]
9Units: mm [in.]3. C-101BAH-AD
Komentáře k této Příručce