Hoshizaki“A Superior Degreeof Reliability”www.hoshizaki.comModelsC-101BAHC-101BAH-DSC-101BAH-ADC-101BAH-ADDSSelf-Contained CubeletHoshizaki America, I

Strany 2

104. C-101BAH-ADDSUnits: mm [in.]

Strany 3 - CONTENTS

11II. Installation Instructions WARNING• The appliance must be installed in accordance with applicable national, state, and local codes and regulation

Strany 4

122. Built-In Installation SiteNOTICE• Do not let the weight of the counter rest on the appliance.• Do not install the appliance in a corner where the

Strany 5 - WARNING, continued

13C. Door1. C-101BAH, C-101BAH-ADa) Door ReversalIf you would like to reverse the door swing, follow the steps below. Otherwise, skip to section "

Strany 6 - A. Construction

144) Remove hinge (B) from the right side of the appliance and the 2 ller screws from the left side. Attach the 2 ller screws to the right side and

Strany 7 - C. Dimensions/Connections

1512 34652. C-101BAH-DS, C-101BAH-ADDSa) Overlay Panel Fabrication and AttachmentIMPORTANTThe overlay panel must be crafted by a professional cabinet

Strany 8 - 2. C-101BAH-DS

16(2) Overlay Panel SpecicationUse the specication that applies to your appliance (C-101BAH-DS or C-101BAH-ADDS) and the directions that follow to p

Strany 9 - 3. C-101BAH-AD

17C-101BAH-ADDS Overlay Panel SpecicationOverlay Panel Height 27 9/16" (700 mm)Overlay Panel Width 14 13/16" (376 mm)Overlay Panel Thicknes

Strany 10 - Units: mm [in.]

183) Screw the 6 threaded wood inserts into the 1/4" holes drilled in the previous step. Make sure that the inserts are threaded straight and tha

Strany 11 - B. Location

19f) Remove hinge (C1) from the top right part of the door, ip it and reattach to the bottom left. Remove hinge (C2) from the bottom right part of th

Strany 12 - (584 mm)

2 WARNINGOnly qualied service technicians should install and service the appliance. To obtain the name and phone number of your local Hoshizaki Certi

Strany 13

209) Temporarily fasten the overlay panel to the door using 2 of the M4×25 pan head screws provided. NOTICE! Ensure that the back surface of overlay p

Strany 14

21Snug the screws, but do not tighten.Sheet Metal BracketOverlay PanelTighten the screws.5) Fasten the overlay panel to the door using the four M4×25

Strany 15 - IMPORTANT

227) Tighten the four M4×25 pan head screws installed in step 5. See Fig. 26.8) Replace the door gasket in its proper orientation. Reinsert the bushin

Strany 16

23D. Setup1) Position the appliance in the selected permanent location.2) Level the appliance from side-to-side and front-to-rear by adjusting the fee

Strany 17

24F. Water Supply and Drain Connections WARNINGWater supply and drain connections must be installed in accordance with applicable national, state, and

Strany 18

25Fig. 30Piping to approved drain. Leave a 2-inch (5-cm) vertical air gap between the end of the pipe and the drain.2-inch (5-cm) air gapFloorDrainShu

Strany 19

26G. Final Checklist WARNINGCHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation. Make sure that

Strany 20 - Fig. 18 Fig. 19

27III. Operating InstructionsA. Important Notes About Usage WARNING• Only qualied service technicians should install and service the appliance.• Fail

Strany 21 - Fig. 24 Fig. 25

28NOTICE• Protect the oor when moving the appliance to prevent damage to the oor.• If using the optional drain pump (HS-5061), test its operation ev

Strany 22 - Fig. 28 Fig. 29

29B. Startup WARNINGAll parts are factory-adjusted. Improper adjustments may adversely affect safety, performance, component life, and warranty covera

Strany 23 - E. Electrical Connection

3IMPORTANTThis manual should be read carefully before the appliance is installed and operated. Read the warnings and guidelines contained in this manu

Strany 24

30IV. MaintenanceThe appliance must be maintained in accordance with the instruction manual and labels provided with the appliance. Consult with your

Strany 25

31A. Maintenance ScheduleThe maintenance schedule below is a guideline. More frequent maintenance may be required depending on water quality, the appl

Strany 26 - G. Final Checklist

32B. Cleaning and Sanitizing InstructionsThe appliance must be cleaned and sanitized at least twice a year. More frequent cleaning and sanitizing may

Strany 27 - III. Operating Instructions

337) Make sure at least 10 minutes have elapsed since you poured the cleaning solution over the extruding head, then move the control switch to the &q

Strany 28

345. Sanitizing Procedure - Final1) Using a clean funnel and hose, pour 1 qt (1 l) of sanitizing solution over the extruding head. Allow the appliance

Strany 29 - B. Startup

35D. CondenserCheck the condenser once a year, and clean if required by following the steps below. More frequent cleaning may be required depending on

Strany 30 - IV. Maintenance

36E. Optional Drain Pump HS-5061If the optional drain pump (HS-5061) is installed, test its operation at least twice a year as outlined below. Note th

Strany 31 - A. Maintenance Schedule

37V. Preparing the Appliance for Periods of Non-UseDuring extended periods of non-use, extended absences, or in sub-freezing temperatures, follow the

Strany 32

3814) Plug the appliance back in, then move the control switch to the "DRAIN" position. 15) Blow out the reservoir outlet hose using the com

Strany 33

39VI. DisposalThe appliance contains refrigerant and must be disposed of in accordance with applicable national, state, and local codes and regulation

Strany 34 - C. Storage Bin Drain

4Important Safety InformationThroughout this manual, notices appear to bring your attention to situations which could result in death, serious injury,

Strany 35 - D. Condenser

40HOSHIZAKI AMERICA, INC.618 Hwy. 74 S., Peachtree City, GA 30269 USA TEL (770) 487-2331 FAX (770) 487-3360 www.hoshizaki.com 1A3094-010

Strany 36 - Discharge Hose

5 WARNING, continued• The appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or

Strany 37

6I. SpecicationsA. ConstructionTop PanelIce Discharge OpeningScoop HolderFront PanelControl SwitchLouverBin Control Thermostat BulbSlopeMagnet CatchD

Strany 38

7C. Dimensions/Connections1. C-101BAHUnits: mm [in.]

Strany 39 - VI. Disposal

82. C-101BAH-DSUnits: mm [in.]

Strany 40 - HOSHIZAKI AMERICA, INC

9Units: mm [in.]3. C-101BAH-AD